What is a single signal and how is it calculated according to the Omnimes system?
In the OmniMES system, the concept of a single signal refers to a precisely defined event or value coming from a specific device, machine, or PLC. This signal is transmitted to the system using the standardized MQTT Sparkplug B format.
Signal configuration - view from OmniMES (first image)
In the first screenshot, we see the status configurator, where the user defines a single signal with the following parameters:
MQTT Topic:
spBv1.0/companyID/DDATA/machineID/Local HMITag (Sparkplug B metric):
MES/Machine6/HMI1/M_STATEValue:
1Data type: Event
Profile: Production
Machine, Line, Factory: Used to map the signal to the correct organizational units in the system.
This means that a single signal in OmniMES is essentially a rule that says:
*"If metric* *Y* with value *Z* appears under topic *X*, treat it as a defined event (e.g. machine started production)."
Receiving the signal - view from MQTT.fx (second image)
Sparkplug B message - MQTT.fx
Here we see a real Sparkplug B message published by a device:
{"timestamp": 1748613351195,"metrics":[{"name": "MES/Machine6/HMI1/M_STATE","dataType": "UInt16", "value": 1 }],"seq": 69 }
In this example, MQTT.fx is listening to the topic:
spBv1.0/companyID/DDATA/machineID/Local HMI
The message contains one metric: MES/Machine6/HMI1/M_STATE with a value of 1.
If the value had been 3 instead, and such a signal was defined in OmniMES, the system would have interpreted it, for example, as the start of a machine failure.
How does OmniMES "calculate" or detect a signal?
It's not a traditional calculation - it's rather a process of detection and matching:
The system subscribes to specific MQTT topics.
For every incoming message:
It parses the list of metrics.
For each metric, it checks if there's a match with a predefined signal.
If the combination of
tag + valuematches a defined signal, it records it as an event with the associated timestamp, machine, and status.
These events are later used for:
KPI calculations (e.g., OEE),
downtime reports,
generating alerts,
machine activity history.
Summary
A single signal in OmniMES is a specific Sparkplug B metric value defined in the status configurator. When that exact value appears in a message on the broker, the system treats it as a meaningful event (e.g., failure, stop, production start).
Comparison example:
Actual signal from the MQTT broker:
{"timestamp": 1748613351195,"metrics":[{"name": "MES/Machine6/HMI1/M_STATE","dataType": "UInt16", "value": 1 }],"seq": 69 }
Signal defined in OmniMES:
Tag:
MES/Machine6/HMI1/M_STATEValue:
1Profile: Failure
If the metric name and value match, the event is triggered in OmniMES.