Machine events

Menu → Maintenance → Machine events

The Machine events screen (formerly History events) is one timeline of a machine, a line or a whole park. It shows in one place what happened to a machine: failures and stops with their reasons, alarms, failure requests and work orders, operator pauses and downtime reason changes. You can write a note on each event - what happened, what was done, what to check next time - and act on it right away: assign a downtime reason, report a failure or go to the alarm, request or work order.

Failures and stops on the timeline are the same segments as in OEE - they are calculated by the same function as the downtime list on the Work time and OEE screen, the loss Pareto and the reports. A stop has the same start, end, reason and loss type here as in OEE.

What the timeline shows

Source

Events

From

Machine state

Failure, Unplanned stop, Planned stop, Changeover, Micro-stop, Running, Other state, Unknown state (a state signal value without a status in the configuration)

state segments from the machine state signal (Status configurator) with the downtime reason

Alarms

Alarm - with its rule, severity, state and acknowledgement comment

the Alarms screen

Maintenance

Maintenance request (from the failure start until the machine is restored), Work order, Maintenance history (status changes, technician work, parts)

the Maintenance screen

Operator and reasons

Operator pause with its reason, Downtime reason change (who, when, before and after)

operator panel, manual reason correction

Notes

Note on a machine or on an event that is not on the list

this screen

The stop type follows the loss type, as in OEE: a stop whose reason is in the changeover category is a Changeover, in the planned category - a Planned stop, and a short stop no longer than the threshold from the Micro-stops screen - a Micro-stop.

Filters

Above the list:

  • Machine park, Line, Machine - the scope; with nothing chosen - all machines,

  • Period - the last 8 h, 24 h, 3 days, 7 days, 31 days or a Custom range (From and To fields with time),

  • Sources - which sources to show (table above),

  • Event types - by default without running, other states, micro-stops and detailed maintenance history, so the list shows what needs attention,

  • Notes - all, only with a note or without a note (e.g. failures nobody wrote anything about),

  • Search - text in the event name, reason, request description and notes,

  • Order - newest or oldest first.

Below the filters there are event type counters for the period (the number and, for stops, the total time). Clicking a counter turns that type on or off on the list.

The period can be at most 31 days. State segments are calculated from machine data every time the screen is shown, so one query covers at most 40 "machine-days" (e.g. one machine × 31 days, a park with 20 machines × 2 days or a plant with 100 machines × about 9 hours). The screen opens on the last 8 hours. For a larger scope it suggests which period you can choose - narrow the park, line or machine. Alarms and maintenance alone (without the Machine state source) have no such limit.

Event list

Each event is a row with a colour bar (the machine status colour or the event type colour) and an icon. The row shows:

  • the event name (machine status, alarm title, request or work order number and title) and its type,

  • start, end (or ongoing) and duration,

  • machine and line, person (operator, technician, reporter),

  • the downtime reason or description,

  • the first note and the number of further notes,

  • a links icon when events are connected - e.g. a failure and a stop alarm or a maintenance request that started during this failure.

Clicking a row opens the event details in a panel on the right.

Event details and notes

The details panel shows all event data: time, source, reason with its source (manual correction, operator pause, rule, none), OEE loss type, alarm severity and state, request or work order status and related events.

Notes. Use Add note to describe what happened and what was done. The note is saved on this event with its author and time and is visible:

  • on the event timeline,

  • on the downtime list on the Work time and OEE screen (OEE tab → Downtimes, Notes column),

  • in the machine history on the machine card in Maintenance.

It is one note - you do not need to copy it anywhere else. A note can be edited or deleted by its author, and any note by an administrator (Administrators group). Adding, editing and deleting go to the Event log (Production category).

The event also shows notes written in other modules - the alarm acknowledgement comment, the manual reason correction note, the operator note on a pause and work order notes. They are marked with their source; you change them in the module they come from.

The Notes → Without a note filter together with the Failure type shows failures nobody described - a ready list for the shift briefing.

Actions on an event

  • Assign reason (failure, stop, pause) - the same manual reason correction as on the Work time and OEE screen: choose a reason from the dictionary and add a note. The change goes to the production event log, and OEE and the Pareto are recalculated at once. Available to users with the OEE, Production orders or Work time and OEE screen.

  • Report failure (failure, stop, alarm) - the request form from Maintenance. For a stop the request can be linked with this stop, also a finished one - the failure start in the request is the stop start, so MTBF and MTTR from requests use the real failure time. Available to users who can report failures (Maintenance, My work orders, Operator panel, Production orders).

  • Assign status (Unknown state) - opens the Signal values (diagnostics) tab with this machine and the event period (with a margin of a quarter of an hour). A message above the list shows the machine and the period, and a signal value without a status has the Add status button. Available to users allowed to configure statuses (tab below). Unknown state is not on the list by default - click its counter above the list.

  • Go to the alarm, Go to the request, Go to the work order, Machine card, OEE and downtime analysis - go to a screen the user has in the menu.

Timeline chart

When a machine is selected, the Show chart button appears. The chart shows the machine states in the period - each status is a colour band on the time axis, so you can see at a glance when the machine was running and when it was stopped.

CSV export

The Export CSV button saves the events with the current filters (up to 20,000 rows) to a CSV file for Excel: start, end, duration, park, line, machine, source, type, event, reason and its source, OEE loss, status, person, details and notes. The export is recorded in the Event log.

Signal values (diagnostics)

The Signal values (diagnostics) tab (formerly State signals) is a tool for the implementer and the administrator for assigning signal values to statuses. It shows the former History events list: segments of state signal values from machine data, including values that do not have a status in the configuration yet. On such a row the Add status button assigns the signal value to a machine and a status profile without going to the Status configurator. Filters: park, line, machine, event type, date, time and days back; with a machine selected - the Event chart.

Only users allowed to configure statuses see the tab - a group with the Structure or Status configurator screen in Access permissions - and the system administrator. Others see only the event timeline on the Machine events screen, without tabs. The Assign status action on an Unknown state event on the timeline also leads to this tab.



Talking to AI about events

You talk to AI about machine events (e.g. "What affects losses most and how can I reduce them?") in your AI assistant connected to OmniMES via MCP - in Claude Desktop, claude.ai or ChatGPT, always with your permissions. You set up the connection in the user menu → AI assistant connection. The AI assistant analysis button was removed from the event timeline in version 5.0.1.

Permissions

The Machine events screen is in the Maintenance group. Groups that had History events have Machine events unchanged - it is the same menu item and the same address, so links from the Main panel tiles work as before. An administrator assigns the screen in Access permissions (the Maintenance group).

  • The screen shows machine states, stops, operator pauses, maintenance requests and notes.

  • Alarms on the timeline are visible to a group that has the Alarms screen, and work orders and maintenance history - to a group with the Maintenance (or My work orders) screen. When part of the data is hidden, the screen shows which sources the missing permissions concern.

  • Notes can be added by anyone with the Machine events, Maintenance or My work orders screen.

  • The Signal values (diagnostics) tab, the Assign status action and the Add status button are available to a group with the Structure or Status configurator screen (permission to save the status configuration) and to the system administrator.

The menu is saved at login - the new layout appears after logging in again.

Limitations

  • A state segment has no number - a note is pinned to the machine and the segment start. If you change the machine status configuration so that the segment starts at a different moment, the note stays on the timeline as a separate Note event at the same moment.

  • A stop that started more than 6 hours before the period start has its start cut to 6 hours before the period on the timeline (the same as in OEE) - extend the period to see the whole stop.

  • The timeline chart is for one machine.