Administrator guide

This guide is for the administrator of an OmniMES installation (with the OmniEnergy module): on-premise or in the OmniPlatform cloud. It brings together the rules for secure commissioning, operation, updating and decommissioning of the system, and the information that the manufacturer provides to users under Annex II to Regulation (EU) 2024/2847 (Cyber Resilience Act, CRA).

Commands, files and configuration variables are described in the Installation - on-premise chapter. This guide refers to its sections (in the text: “Installation, section …”) instead of repeating them. The API security settings are described in detail in the BEZPIECZENSTWO_API.md file of the installation package.

The table in section 15 shows where in this guide each piece of information required by Annex II of the CRA can be found. Items marked (to be confirmed by the manufacturer) describe matters that the manufacturer has not yet settled bindingly. We will complete them in the next version of this guide.

1. Manufacturer and security contact

Item

Details

Manufacturer

Multiprojekt Automatyka Sp. z o.o., Siwka 11, 31-588 Kraków, Poland

Website

https://www.omnimes.com

Single point of contact (technical support and vulnerability reporting)

support@omnimes.com

Vulnerability reporting and handling policy

https://www.omnimes.com/en/security (also the https://www.omnimes.com/.well-known/security.txt file)

Security advisories

https://www.omnimes.com/en/security/advisories

Version support period

https://www.omnimes.com/en/security/support

Changelog

https://www.omnimes.com/en/changelog

How to report a vulnerability. Write to support@omnimes.com: what the problem concerns, the OmniMES version (application footer), the steps that lead to the problem and its possible consequences. Do not include passwords or keys. We confirm receipt within 5 business days and keep you informed about further handling. Fix deadlines are counted from the confirmation of the vulnerability, by CVSS 3.1 severity: critical - within 14 days, high - within 30 days, medium - within 90 days, low - in one of the next planned releases. Please do not disclose details until a fix is available.

2. Product and its identification

  • Name: OmniMES, with the OmniEnergy module.

  • Type: MES/EMS software for monitoring production and energy use.

  • Delivery: on-premise installation from the installation package (Docker containers) or an instance in the OmniPlatform cloud.

  • Components sharing one version number: API, web interface, stream (MQTT data collection) and the MCP server. The package also contains third-party components: the PostgreSQL database with TimescaleDB, the EMQX MQTT broker, Redash and - in the full installation - Ollama.

  • Version: in the application footer, in the VERSION file of the installation package and in the output of omnimes status (Installation, section 16.4). The number has the form X.Y.Z (Installation, section 8.2). The changes in each version are described in the changelog.

3. Intended purpose, environment and security properties

3.1. Intended purpose and essential functions

OmniMES collects data from machines, meters and communication gateways (MQTT, Sparkplug B) and uses it to:

  • show machine states and indicators (OEE, MTBF, MTTR), alarms and event history,

  • manage production orders, the schedule, material lots and maintenance,

  • calculate energy use and ISO 50001 indicators (OmniEnergy),

  • produce reports and BI dashboards (Redash),

  • exchange data with ERP systems,

  • provide App Studio applications and an AI assistant through the MCP server.

3.2. What OmniMES does not do

  • OmniMES is not a control system or a machine safety system. It reads data from devices and does not send control commands to machines. The only message it sends to gateways is the Sparkplug B request to send the data description again (“rebirth”). Do not use OmniMES for machine safety functions, interlocks or process control.

  • Indicators and reports are only as accurate as the signals from the devices. Do not base decisions on which people's safety depends solely on OmniMES data.

  • The AI assistant and App Studio use AI models. Check the assistant's answers and AI-built applications before using them in production.

3.3. Deployment models and division of responsibilities

Area

On-premise installation

OmniPlatform cloud

Server, operating system, Docker

customer

manufacturer

Network, firewall, encrypted access (VPN or HTTPS)

customer

manufacturer (HTTPS with a certificate for the instance address)

OmniMES updates

the customer's administrator or the OmniMES service team in an agreed maintenance window (Installation, section 8.2)

manufacturer

Backups

the kopie service in the installation; the customer provides the off-server backup location (section 6.5)

(to be confirmed by the manufacturer)

Accounts, groups, permissions, tokens

customer

customer

Gateways and devices (MQTT accounts, TLS)

customer

customer

AI providers, ERP integrations, email

customer

customer

3.4. Required environment (on-premise)

  • A server with Linux (Debian or Ubuntu Server LTS) and Docker Engine, used only by OmniMES. Hardware requirements are described in the Hardware requirements chapter. Windows with Docker Desktop is suitable for tests and demonstrations (Installation, section 10.4).

  • The server in a separate zone of the plant network. Do not expose OmniMES ports directly to the internet. Access from outside the plant only via VPN or through a reverse proxy with HTTPS (section 6.3).

  • Gateways and devices in an OT network separated from the office network. Gateways connect to the broker over TLS (port 8883) with their own accounts.

  • A synchronised server clock (NTP). It is checked by omnimes preflight (Installation, section 16.2).

  • A place for backups outside the server: an SFTP server, S3-compatible storage or a network drive (Installation, section 15.3).

  • A separate OmniMES account for every person.

In the OmniPlatform cloud the manufacturer provides the server, network, HTTPS and updates. The customer is responsible for accounts, permissions, tokens and device configuration.

3.5. Security properties of the product

  • Unique passwords and keys for every new installation (from version 4.12.0) and a forced administrator password change at the first login.

  • Group screen permissions enforced by the server (enforce mode), protected accounts that only a superuser can change (Administration).

  • Sign-in protection: lock after failed attempts, password rules checked by the server (at least 12 characters), session expiry, sign out from all devices.

  • API secure mode: responses only under the installation's addresses, browser requests only from the front-end address, no error details. The API description is available only after signing in.

  • Event log: sign-ins, access denials and changes to accounts, permissions, tokens and settings; entries cannot be changed; forwarding to a SIEM via syslog.

  • MQTT broker: a separate account for every gateway, access rules that deny by default, TLS 1.2 and 1.3 (MQTT accounts).

  • Services connect to the database with their own accounts without administrator rights (Installation, section 7.3).

  • Administration panels and services without sign-in reachable only from the server (Installation, section 1).

  • Encrypted backups with checksums and a monthly restore test (Installation, section 15).

  • Updates with a backup and automatic rollback on error (Installation, section 8).

  • System files (reports, documents, attachments) only for authorised users, through short-lived signed links.

  • Protection against the server opening internal addresses (SSRF) and a content security policy (CSP) in the interface.

  • A /health status address without sensitive data, healthchecks and automatic restart of services (Installation, section 14).

  • AI assistant with a personal token and the user's permissions, and a change mode: right away, as proposals for approval, or read only (AI assistant connection).

  • Vulnerability scan of components (SBOM) for every release and weekly for the latest version.

4. Known risks and foreseeable misuse

The following situations may lead to significant risk to data security and continuity of operation. Most of them result from configuration that the administrator changes.

Situation

Consequence

What to do

OmniMES ports (80, 8091, 8090, 5000, 1883, 8083) forwarded from the internet without VPN or HTTPS

interception of passwords and tokens, sign-in attempts from the internet

VPN or a reverse proxy with HTTPS, firewall (sections 6.3 and 6.4)

permission control in audit or off mode (e.g. after an update from an older version)

users can read and change data outside their screens

OMNIMES_RBAC_MODE=enforce after reviewing the rbac --odmowy report (Installation, section 8)

BI data in loguj or otwarty mode

production data readable without sign-in

OMNIMES_DATABI_AUTH=wymagaj (Installation, section 12.1)

API in compatibility mode (no OMNIMES_SECURITY or "*" in the addresses)

error details and requests from any website

installation addresses in allowedHosts and corsAllowedOrigins (BEZPIECZENSTWO_API.md)

DANE_DOSTEPOWE.txt left on the server, .env files readable by everyone

anyone with server access knows the passwords and keys

copy the data into a password manager and delete the file; chmod 600 omnimes/.env redash/.env (Linux)

installation set up from a package older than 4.12.0 with the package's passwords and keys

access for anyone who knows the package

change the passwords (Installation, section 7), the “Secrets from the installation package” report after the update and key replacement by the service team (Installation, section 8)

shared MQTT account emqx and port 1883 without TLS after gateways have moved to their own accounts

fake data from any device in the network, data interception

gateway accounts, TLS 8883, disabling the shared account and closing port 1883 (MQTT accounts, Installation, section 10.3)

administration panels and Ollama open to the whole network (OMNIMES_*_BIND=0.0.0.0)

access to databases, the broker and AI models bypassing OmniMES sign-in

keep 127.0.0.1, connect through an SSH tunnel (Installation, section 1)

backup key kopie_age.key only on the server, backups only on the server disk

after a server failure or theft the data cannot be restored

key in a password manager or safe, off-server backup (section 6.5)

the omnimes/kopie directory copied off the server

unencrypted database copies in an uncontrolled place

send only the encrypted backups from omnimes/kopie_zapasowe off the server

PostgreSQL data source in Redash using the database administrator account

every query author has full access to the database server

the omnimes_redash_ro account (Installation, section 7.3)

public Redash dashboard link with confidential data

anyone with the link sees the data

treat the link like a password, disable unused links

Custom (JavaScript) charts in Redash enabled for untrusted authors

foreign code in users' browsers

enable only for trusted authors (Installation, section 8)

the Users and Access permissions screens in ordinary groups

takeover of administrator rights

only for people trusted like an administrator

an account used by several people, Kiosk account for a personal account

the Event log does not show who acted; session without expiry

an account for every person; Kiosk account only for shop-floor workstations

assistant service account (shared MCP token) on without need

assistant changes without a user name

personal connections, service account off (General configuration, AI tab)

external AI provider without a data decision

production data goes to the AI provider

decision of the data owner; for confidential data a local model (Ollama)

App Studio application at the Administrative level without review

the application changes accounts and settings

the level only after reviewing the version (App Studio)

trustedProxies with a whole network (e.g. 0.0.0.0/0), publicApiDocs: true

bypassing the sign-in attempt limit, API route map without sign-in

only your own proxy addresses; API description after sign-in (BEZPIECZENSTWO_API.md)

no updates

known vulnerabilities stay in the installation

update to the latest version (section 8)

OmniMES used for control or machine safety functions

-

the system is not intended for this (section 3.2)

5. Secure commissioning

Order of steps for a new on-premise installation, before users get access:

  1. Requirements: omnimes preflight - Docker, memory, disk space, ports, time (Installation, section 16.2).

  2. Installation: omnimes install (Installation, section 16.3) or the installation script (section 2). Result WYNIK INSTALACJI: OK.

  3. Credentials: copy omnimes/DANE_DOSTEPOWE.txt into a password manager, together with the backup key (KOPIE_KLUCZ_AGE), and delete the file from the server. On Linux restrict reading of the files with passwords: chmod 600 omnimes/.env redash/.env.

  4. First sign-in and licence: your own administrator password (Installation, section 3.3), licence key (section 4).

  5. Addresses and security modes: the installer sets the API secure mode, OMNIMES_RBAC_MODE=enforce and OMNIMES_DATABI_AUTH=wymagaj. When users open OmniMES under another name or address (e.g. through a proxy), add it to OMNIMES_SECURITY (Installation, section 12.1; BEZPIECZENSTWO_API.md).

  6. Accounts and groups: separate accounts for people, groups with a minimal set of screens, the omni account only for administration (section 6.8).

  7. Gateways: an MQTT account for every gateway and a TLS connection (port 8883) with the CA certificate (MQTT accounts, Installation, section 10.3).

  8. Firewall and external access: sections 6.3 and 6.4.

  9. Backups: backup key off the server, off-server backup, omnimes backup --test (Installation, sections 15 and 16.7).

  10. Monitoring: the /health address in the monitoring system, system alarm rules with notifications, syslog to the SIEM (sections 6.7 and 6.10).

  11. AI: decide whether and with which AI provider the system connects, the assistant change mode, the assistant service account off (General configuration, AI tab).

  12. Check: omnimes status ends with WYNIK STATUSU: OK (Installation, section 16.4).

In the OmniPlatform cloud the manufacturer installs and configures the instance (steps 1-3, 5 and 8). The sign-in details are in the OmniPlatform panel (Show Access). The customer's administrator changes the received password to their own and performs steps 6, 7, 10 and 11. Instance backups: section 3.3.

6. Secure operation - checklist

6.1. Passwords and accounts

  • Every person has their own account. Shared accounts only for shop-floor workstations, with the Kiosk account switch (Administration).

  • The omni account (superuser) is for administration only - it has access to everything regardless of groups.

  • Passwords are checked by the server: at least 12 characters, not similar to the login, not common. After 5 failed attempts within 15 minutes the account is locked. Unlock in Administration → Users removes the lock; when the only administrator is locked - docker compose exec api python manage.pyc odblokuj_konto <login> (in the omnimes directory).

  • For a person who leaves, delete the account or change its password and use Sign out from all devices - this ends their sessions and API token. Also revoke their AI assistant tokens (section 6.9).

  • System passwords: database and the shared broker account - set_pass.py (Installation, section 7); EMQX panel - in the broker panel; Redash administrator - in Redash (Installation, section 5).

  • Sign-in rules (password length, session time, maximum API token age, forced change of a weak password) are set in OMNIMES_SECURITY, subsection login (BEZPIECZENSTWO_API.md, “Logowanie, hasła i sesje”).

6.2. Service database accounts (PostgreSQL)

  • Services connect to the database with their own omnimes_* accounts without administrator rights. Check the state with the stan step of the role_pg script (Installation, section 7.3). When the update script printed !! OSTRZEZENIE, the service stayed on the administrator account - clarify the cause with the OmniMES service team.

  • Set OMNIMES_PG_ROLE=0 (back to the administrator account) only at the service team's request.

  • The database administrator account omni is only for installation, backups and updates. The database has no port on the server - only services in the Docker network connect to it. Start Adminer for the time of your work and stop it afterwards (Installation, section 1).

  • PostgreSQL data source in Redash: only the omnimes_redash_ro account (read only).

6.3. Encryption: broker TLS and HTTPS

  • Gateways connect to the broker over TLS on port 8883 and verify the broker certificate with the ca.crt file (MQTT accounts). A company certificate goes into omnimes/konfiguracja/mqtt_tls (Installation, section 10.3). Additional server names and addresses in the certificate the broker creates: OMNIMES_MQTT_TLS_HOSTY (Installation, section 12.1).

  • When all gateways work over TLS, disable the shared emqx account and close port 1883 (OMNIMES_MQTT_BIND=127.0.0.1, then docker compose up -d broker).

  • The on-premise installation works over HTTP inside the plant network. For access from outside the plant network use a VPN or a reverse proxy with HTTPS (your own certificate) in front of the web interface, the API, the MCP server and Redash. With HTTPS:

    • set OMNIMES_API_HOST to the https://… address of the API and run docker compose up -d --no-deps www (Installation, section 12.1),

    • add the addresses to allowedHosts and corsAllowedOrigins, and the proxy address to login.trustedProxies (BEZPIECZENSTWO_API.md),

    • set the live preview in the browser to WebSocket with TLS, port 8084 (General configuration). The browser connects only if it trusts the broker certificate - use a company certificate in omnimes/konfiguracja/mqtt_tls (the same certificate serves ports 8883 and 8084).

  • In the OmniPlatform cloud HTTPS is on from the start. Connect devices to the instance broker over TLS (8883), not 1883.

6.4. Firewall and ports

The full list of ports is in Installation, section 1. Recommended access:

Port

Service

Default access

Who should have access

80 (OMNIMES_WWW_PORT)

web interface

network

users

8091

API

network

users' browsers, integrations, monitoring system

5000

Redash

network

dashboard users

8082

Redash through nginx

network

not used by OmniMES - block it in the firewall if nobody uses it

8090

MCP server

network

computers with an AI assistant

8883

MQTT over TLS

network

gateways and devices from the OT network

1883

MQTT without encryption

server (new installation), network (installation updated from EMQX 4)

only until gateways have moved to TLS

8083, 8084

MQTT over WebSocket (8084 with TLS)

network

users' browsers (live preview)

18083

EMQX broker panel and API

server

administrator, through an SSH tunnel

8079

Adminer (on demand)

server

administrator, through an SSH tunnel

11434

Ollama

server

OmniMES only (Docker network)

-

PostgreSQL

no port

only services in the Docker network

  • SSH access to the server only from the administrators' network.

  • On Linux, Docker publishes container ports bypassing ufw rules. Restrict access to OmniMES ports with a network firewall in front of the server or with rules in the DOCKER-USER chain.

  • The server needs outgoing connections for installation and updates (list of addresses in Installation, section 16.2) and for the services you enable: AI providers, email, off-server backups, syslog and ERP. Other outgoing connections can be blocked. Installation without internet access: an offline package from the OmniMES service team.

6.5. Backups and restore test

  • The kopie service makes a backup every day at 2:30 and of telemetry once a week. Backups are encrypted, and once a month the service checks that they can be restored (Installation, section 15.1).

  • Keep the backup key (omnimes/konfiguracja/kopie_age.key) off the server. Without it backups cannot be restored (Installation, section 15.2).

  • Off-server backup: SFTP, S3 or a network drive (Installation, section 15.3). A backup on the server disk does not protect against a disk failure or server theft.

  • After installation and after larger changes: omnimes backup --test. Once a year rehearse a full restore on a separate server (Installation, section 15.4) and record how long it took.

  • An alarm rule Backup failed or overdue with an email notification (System status).

  • The omnimes/kopie directory (copies made before updates) is not encrypted - it stays on the server.

  • The System settings → Backup screen exports the system configuration (Backup). It does not replace the database and file backups of the kopie service.

How much data can be lost and how long a restore takes: section 9.

6.6. Updates and rollback

  • Follow the security advisories and the changelog. Security fixes are only in the latest version (section 8).

  • Before an update, copy the files from the new package (Installation, section 8.2, step 2). The update script backs up the databases and settings.

  • omnimes update ends with WYNIK UPDATE: OK. The result WYCOFANA means the previous version is running; the cause is in the result line and in the log in omnimes/kopie (Installation, sections 8 and 16.6).

  • After an update check: the version in the footer, sign-in, live data in Monitoring, downloading a report, /health and omnimes status. Read the script report: “Secrets from the installation package”, the warning about API addresses, the Redash extension.

  • A problem noticed after a successful update: omnimes rollback. Data saved in the omni and omni_queue databases after the update is lost, measurements stay (Installation, section 16.6).

6.7. Logs and the Event log

  • The Event log records successful and failed sign-ins, locks, access denials, and changes to accounts, groups, permissions, tokens, keys, the licence and settings. It is visible to the superuser and to a group with this screen.

  • Retention: 365 days by default. Do not shorten it below one year. Keep entries longer in the SIEM.

  • Syslog to the plant SIEM: Administration → Event log → Syslog and retention, preferably over TLS (usually port 6514).

  • Review weekly: failed sign-ins and locks, access denials, permission changes, new tokens and keys.

  • Report of operations rejected by permission control: docker compose exec api python manage.pyc rbac --odmowy (in the omnimes directory).

  • Container logs: docker compose logs <service> in the omnimes directory. Docker limits their size (file rotation). Logs of updates and of omnimes tool commands are in omnimes/kopie.

6.8. Permissions (RBAC)

  • enforce mode - the server blocks operations outside the group's screens (Administration, “Server-side permission control”).

  • Least privilege: a group gets only the screens needed for its work.

  • Give the administrative screens (Users, Access permissions, General configuration, Backup, License, Event log, System status, MQTT accounts) to administrators only. Only a superuser assigns users to the Admins group.

  • Review groups and accounts at least once a year and at every change in the team.

  • The AI assistant and App Studio applications work with the user's permissions. The assistant change mode is set by the administrator in General configuration, AI tab. Only a superuser gives an App Studio application the Administrative level, after reviewing the version.

6.9. Tokens and keys

Token or key

Used for

Where

How to revoke or replace

account API token and browser sessions

scripts, integrations, sign-in

user account

Sign out from all devices or a password change; token age limit apiTokenMaxDays

personal AI assistant token (oms_…) and OAuth connections

AI assistant (MCP)

user menu → AI assistant connection; all tokens: General configuration → AI

Revoke, Disconnect

assistant service account token (shared MCP token)

automation

General configuration → AI, Advanced panel

Generate a new token or turn the service account off

ERP integration key (omk_…)

the ERP system sending orders

System settings → ERP integrations, API key tab

a new key invalidates the previous one; deleting the integration disables its key

Redash token (Redash administrator API key)

OmniMES-Redash connection

General configuration → Redash (known only to the server)

a new key in Redash and in OmniMES (Installation, section 5.3)

public Redash dashboard links

dashboards in frames

Redash, dashboard → Share

disable the link in Redash

AI provider keys

AI functions

General configuration → AI → Provider connections

a new key in the provider's console and in the connection

gateway MQTT account passwords

gateways

Administration → MQTT accounts

New password, disabling or deleting the account

secretKey, markKey in OMNIMES_SECURITY

/admin panel sessions, time marks

omnimes/.env

BEZPIECZENSTWO_API.md (changing secretKey signs users out of the /admin panel)

OMNIMES_SECRETS_KEY

encryption of Redash account passwords

omnimes/.env

do not change (Installation, section 12.1)

backup key kopie_age.key

backup encryption

omnimes/konfiguracja and a copy off the server

do not change without agreeing with the service team - older backups need the old key

licence key

licence

omnimes/konfiguracja

a new key from the manufacturer's licence panel (License)

broker certificate and key

MQTT TLS

omnimes/konfiguracja/mqtt_tls

new files and docker compose restart broker; with a new CA, a new ca.crt in the gateways

SFTP, S3, email, syslog, ERP passwords

external services

omnimes/.env, General configuration, ERP integrations

change in the target service and in OmniMES

  • Copy tokens and passwords shown “only once” into a password manager right away.

  • Revoke unused tokens. The Last used column shows which ones are unused.

  • Backups contain the installation settings with passwords - they are protected by encryption, so protect the backup key.

6.10. Health monitoring

  • Poll the /health address from the monitoring system every 30-60 s. Raise an alarm when the HTTP code is not 200 or the status is degraded (Installation, section 14.1).

  • omnimes status from the task scheduler: exit code 0, 4 or 1 (Installation, section 16.4). It sees containers, backups and disk space, which /health does not.

  • The System status screen and system alarm rules with notifications: no data from the stream, low disk space, backup failed or overdue, task queue clogged, email sending errors, service unavailable.

  • Automatic restart of unhealthy services is provided by the autoheal container (Installation, section 14.3). When the task queue is stuck, system alarms can be run from the server's scheduler: docker compose exec -T api python manage.pyc alarmy_systemowe (in the omnimes directory).

  • Licence expiry: banner and the License expiring alarm rule (License).

6.11. Incident response

When you suspect an intrusion, a password leak or unauthorised changes:

  1. Limit the damage. Cut off external access (firewall, VPN). Stop the affected service (e.g. docker compose stop mcp). Stop the database, broker and stream only when necessary - without them no machine data is collected.

  2. Preserve evidence before you change anything: Event log export to CSV, omnimes support-bundle, container logs, a backup with omnimes backup. Do not delete backups made before the incident.

  3. Revoke access: change the passwords of the affected accounts and use Sign out from all devices; revoke AI assistant tokens, ERP keys and the assistant service account token; change MQTT account passwords. When a .env file may have leaked, change the system passwords (Installation, section 7) and contact the service team about the installation keys.

  4. Restore operation: remove the cause, if needed restore data from a backup made before the incident (Installation, section 15.4) and update the system to the latest version.

  5. Notify the manufacturer: support@omnimes.com - description, time, version and the diagnostic bundle (without passwords). The manufacturer checks whether the cause is a vulnerability of the product and, if so, releases a fix and a security advisory.

  6. Your own obligations: an incident may have to be reported by your organisation (e.g. under national cybersecurity laws) - follow your company's procedures.

  7. After the incident: review accounts, groups, tokens and firewall rules, and record the lessons learned.

6.12. Periodic review

When

What to check

daily (automatic)

backup and system alarms - react to notifications

weekly

Event log: failed sign-ins, locks, access denials; omnimes status

monthly

restore test result, security advisories and changelog, free disk space, unused tokens

quarterly

update to the latest version (security fixes - within the deadlines given in the advisories), unused MQTT accounts, public Redash links

yearly

groups and permissions, personal accounts, App Studio applications at the Administrative level, firewall rules, restore rehearsal on a separate server, this guide

at a change in the team

accounts, tokens and passwords known to the person who leaves

7. Changes that affect data security

Before any of the following changes, assess its effect and record the decision (who, when, why):

  • turning off permission control (OMNIMES_RBAC_MODE=audit or off) or switching BI data to loguj or otwarty,

  • removing OMNIMES_SECURITY, "*" in the addresses, publicApiDocs: true, changing trustedProxies,

  • opening firewall ports, OMNIMES_*_BIND=0.0.0.0, forwarding ports from the internet,

  • reopening port 1883 or enabling the shared MQTT account,

  • public Redash dashboard links, Custom (JavaScript) charts in Redash, PostgreSQL data sources in Redash,

  • giving a group administrative screens (section 6.8),

  • the Administrative level of an App Studio application, the Apply right away assistant change mode, turning on the assistant service account,

  • a new AI provider or a new assistant via MCP,

  • a new ERP integration (key, webhook, SFTP, exchange directory),

  • changes to .env, docker-compose.override.yaml and other services installed on the OmniMES server,

  • turning off backups (OMNIMES_KOPIE=nie), the restore test or the automatic restart, shortening the Event log retention,

  • moving services back to the database administrator account (OMNIMES_PG_ROLE=0).

Changes to the product itself. An update does not change the modes stored in omnimes/.env (e.g. permission control, OMNIMES_SECURITY) - new recommendations are given in the changelog and security advisories. Do not change the scripts, Docker files and images from the package: the update overwrites them, and a change may switch off protections. Save your own container configuration changes only in docker-compose.override.yaml (Installation, section 12.3).

8. Security updates and support period

Type of support. We release security fixes in the latest OmniMES version. Updating to it is free of charge for every customer with a valid licence, also one using an older version. We handle reports concerning older versions within their support period and deliver the fix as an update to the latest version (Installation, section 8.2). Technical support: support@omnimes.com.

Support period. Each version has a support period of at least 5 years from its release. The end date (month and year) for each version is given in the table on the Support period and updates page. Before a version reaches the end of its support period, we inform the customers who use it. Versions older than 4.0.0: end of support (to be confirmed by the manufacturer).

How to install updates. On-premise: Installation, sections 8 and 16.6 (update with a backup and automatic rollback). Which versions can move directly to the latest one is shown in the table in Installation, section 8.2. Installations maintained by the OmniMES service team are updated by the service team in an agreed maintenance window. OmniPlatform cloud: instances are updated by the manufacturer.

How you learn about updates. New versions: the changelog (the “Security” section of each version). Security fixes: security advisories; customers affected by a vulnerability are informed directly. Download the installation package only from the manufacturer's licence panel or from the OmniMES service team.

Automatic updates. An on-premise installation does not install updates automatically - the administrator chooses the time, so there is no setting to turn off. Postponing a cloud instance update at the customer's request: (to be confirmed by the manufacturer).

9. Backups and restore - RPO and RTO

RPO is the maximum amount of data that can be lost. RTO is the time to restore operation. Values for an on-premise installation with the kopie service in its default settings (Installation, section 15.4):

Situation

RPO - maximum data loss

RTO - restore time

failed update

none

a few minutes, automatic (update rollback)

database damage, data mistake

configuration and production: up to 24 h; telemetry: since the last weekly backup

a few minutes for the configuration database; telemetry - depending on its size

server or disk failure

as above, only when the backup and the key are off the server

a new server (approx. 30-60 min) and a restore from the backup

  • Lower RPO for measurements: OMNIMES_KOPIE_TELEMETRIA=codziennie (more space for backups). The backup time is set by OMNIMES_KOPIE_GODZINA (Installation, section 15.3).

  • Shorter RTO after a server failure: a prepared spare server with Docker and the installation package of the same version.

  • The telemetry restore time of your installation can be measured with a test: docker compose exec -e OMNIMES_KOPIE_TEST_TELEMETRIA=tak kopie omnimes-kopie test.

  • OmniPlatform cloud: instance RPO and RTO (to be confirmed by the manufacturer).

10. Troubleshooting

Symptom

Most common cause

What to do

sign-in screen: network error or sign-in error from a new address

address not in allowedHosts or corsAllowedOrigins; the page address instead of the API (port 8091) in the API URL field

Installation, section 3.2; add the address to OMNIMES_SECURITY and run docker compose up -d --no-deps api

account locked

5 failed sign-in attempts

Unlock in Administration → Users or odblokuj_konto (section 6.1)

message “You do not have permission to perform this operation.”

enforce mode, group without the screen

give the group the screen; rbac --odmowy report

no live data, stream in degraded state

broker, gateway MQTT account, CA certificate, port

/health, omnimes status, System status; gateway account and port 8883 (Installation, section 10.3)

gateway does not connect over TLS

no ca.crt in the gateway, server address not in the certificate

download the CA certificate (MQTT accounts); names in the certificate: OMNIMES_MQTT_TLS_HOSTY or a company certificate

update ended with WYCOFANA

one of the steps failed

the previous version is running; the cause is in the result line and in omnimes/kopie/aktualizacja_<date>.log; repeat after removing the cause

exit code 3 or BLAD KRYTYCZNY

update or rollback error

do not repeat - contact the OmniMES service team

Redash buttons open the Redash sign-in page with a note about a missing extension

Redash has not been updated

updated_redash or omnimes update redash

reports, alarms and schedules do not run (qcluster)

background task queue

the Task queue tile on the System status screen, omnimes status; diagnostic bundle for the service team

containers restart, OOMKilled

not enough RAM

16 GB RAM; in Docker Desktop the memory assigned to Docker (Installation, section 16.2)

backup failed

no space, SFTP or S3 error

docker compose exec kopie omnimes-kopie stan; settings in Installation, section 15.3

port 80 busy

another service on the server

Installation, section 10.1

“License expired” banner or screen

the licence has expired

License

When a problem persists: omnimes support-bundle (Installation, section 16.5) and a message to support@omnimes.com with a description and the diagnostic bundle.

11. Decommissioning and removal of data

On-premise installation:

  1. Keep what you must. Decide which data has to be kept (e.g. by law or contract) and back it up: omnimes backup --telemetria (encrypted backup - keep the key) or pg_dump of the individual databases (Installation, section 13), an Event log export to CSV, the reports and documents you need.

  2. Disconnect data sources: disable the gateway MQTT accounts, the ERP integrations (deleting an integration disables its key) and syslog forwarding.

  3. Revoke external access: AI assistant tokens and OAuth connections (also the OmniMES extensions in Claude Desktop), the assistant service account, AI provider API keys in their consoles, VPN accounts, firewall and proxy rules, DNS entries.

  4. Uninstall: omnimes uninstall (Installation, section 16.8) or uninstall_all (section 9). Containers, the volumes with databases and system files, and the images are removed.

  5. Check: docker volume ls and docker image ls show no OmniMES or Redash volumes or images (including the old omnimes_api_data and omnimes_www_data volumes).

  6. Delete the remaining files: the installation package directory with the .env files, the omnimes/konfiguracja directory (licence key, backup key, broker certificates), omnimes/kopie and omnimes/kopie_zapasowe, and the off-server backups (SFTP, S3, network drive) that you do not need to keep.

  7. Storage media: before a server or disk is reused or disposed of, wipe it securely according to your company's rules.

  8. Licence: inform the manufacturer that you no longer use the licence (support@omnimes.com).

Restoring the factory state: uninstall (step 4) and install again from the package (section 5).

OmniPlatform cloud: after the subscription ends, the instance (the server with its data) is deleted. Deadlines for deleting the instance data and its backups, and a data export before deletion at the customer's request - (to be confirmed by the manufacturer).

12. Information for integrators

  • REST API (port 8091): token authentication (POST /auth/, then the Authorization: Token <token> header); Basic authentication is disabled. For an integration create a separate account in a group with a minimal set of screens - in enforce mode the account has exactly those permissions. By default the token does not expire: store it like a password and delete the account when the integration is retired. The API description (/swagger/, /redoc/) is available after signing in (BEZPIECZENSTWO_API.md).

  • ERP orders API (/erp-api/v1/): an omk_… integration key, separate for each integration; the OpenAPI description can be downloaded on the API key tab (ERP integrations).

  • MCP server (port 8090): AI assistants connect with the user's personal token or OAuth sign-in and work with the user's permissions; the assistant's changes appear in the Event log with the source AI assistant (MCP) (AI assistant connection). The assistant sends the AI provider the data the user asks about - the choice of provider is up to the data owner.

  • MQTT, Sparkplug B (TLS 8883): every gateway has its own account that publishes only in its own group and node and does not send commands to machines (MQTT accounts).

  • Redash: dashboards fetch data through the API with the redash_bi account token, which can only read BI data. A public dashboard link gives access to anyone who has it.

  • App Studio: an application runs on the account of the person who opened it and can do only what the permissions of both that person and the author allow; only a superuser gives the Administrative level (App Studio).

  • Monitoring and SIEM: /health and the omnimes status exit codes (section 6.10), syslog in RFC 5424 format (section 6.7).

  • OmniMES as part of another product: the integrator receives from the manufacturer this guide, the Cybersecurity & Compliance (CRA) chapter, the software bill of materials (SBOM, section 13) and the security advisories. Interfaces and ports are described in section 6.4, security properties in section 3.5. Report vulnerabilities in OmniMES to support@omnimes.com.

13. Software bill of materials (SBOM)

We prepare a software bill of materials (SBOM) in CycloneDX format for every version since 4.8.0. It is available on request to customers who have purchased the product and to market surveillance authorities: support@omnimes.com. The SBOM is not included in the installation package - a full list of component versions would make an attack easier.

14. EU declaration of conformity

The manufacturer carries out the CRA conformity assessment under internal control (module A). We will issue the EU declaration of conformity before 11 December 2027. Internet address of the declaration: (to be confirmed by the manufacturer) - we will publish it once the declaration is issued. The state of product adaptation is described in the Cybersecurity & Compliance (CRA) chapter.

15. CRA Annex II requirements - where in this guide

Point

Information required by Annex II

Section

1

name, address and contact details of the manufacturer

1

2

single point of contact for reporting vulnerabilities and where the coordinated vulnerability disclosure policy can be found

1

3

name, type and unique identification of the product

2

4

intended purpose, security environment, essential functions and security properties

3

5

known or foreseeable circumstances and misuse that may lead to significant risks

4

6

internet address of the EU declaration of conformity

14

7

type of security support and end date of the support period

8

8a

measures at initial commissioning and throughout the lifetime of the product

5, 6

8b

how changes to the product can affect the security of data

7

8c

how security updates can be installed

8, 6.6

8d

secure decommissioning and removal of user data

11

8e

how automatic installation of updates can be turned off

8

8f

information for the integrator

12

9

where the software bill of materials (SBOM) can be accessed

13