# 3D Hall

:::tip
Menu → Preview → 3D Hall

:::

  
The **3D Hall** module (called **Hologram** up to version 4.11) shows the production hall as a **3D model** — with machines, lines, racks, transport aisles, forklifts and material flow. Every machine in the model is linked to a machine in the OmniMES structure, so its **state and measurements update live** from the data on the MQTT broker. The same model also runs in **flow simulation** mode, where you can check throughput, queues and the bottleneck without affecting production.

The hall model is built by an **AI assistant over the MCP server** (see *Building and extending the model*) or comes from a **3D file in the .glb format** — e.g. from a CAD program, from Blender or from a machine maker (see *Hall from a .glb file*). In the application you view, configure and simulate it, and connect OmniMES machines to parts of the model.

 ![](https://docs.omnimes.com/api/files.get?sig=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJrZXkiOiJ1cGxvYWRzLzRlMDdmZmNhLThmZjAtNDYxYy1iYjEyLTA2OTEyZGRiOGQzNi9iNjBlNjllMC0xYjg1LTQzY2YtYjU1ZC05MDkwYTIxZDI3MTkvaG9sb193aWRvay5wbmciLCJ0eXBlIjoiYXR0YWNobWVudCIsImlhdCI6MTc5NTQxMDAwMCwiZXhwIjoxNzk1NDk2NDAwfQ.OkIJMd9yx8PqBZ2Vpi7Y6_iyMmTrJLCSTukxRm-iMN4)

## Toolbar

* **3D hall selector** — the models saved in the system, with the current version number,
* **Live state / Simulation** — switches the model mode,
* **Scope** — what the model covers: the whole plant, selected lines or selected machines,
* **Station cards layout** — cards on the **Side**, at the **Bottom** or **Hidden** (on narrower screens the buttons show icons only),
* **Layers** — what the model shows: machine names, state, parameters, utility consumption, zones, material flow and lighting (see *View layers*),
* **Full screen** — the model on the whole screen, e.g. on a shop-floor monitor; go back with **Exit full screen**,
* **Connect machines** — only in a hall from a .glb file: connects OmniMES machines to parts of the model by clicking the model (see *Connecting machines to model parts*),
* **Settings** and **Version history** — described later in this chapter. **Connect machines**, **Settings** and **Version history** are shown to a superuser and to users whose group has the **3D Hall settings** screen in [**Access permissions**](https://docs.omnimes.com/doc/administration-IPR8voQzB6) (Settings and Version history from version 4.8.0).

The selected 3D hall, mode, cards layout, layers and simulation speed are remembered in the browser. While the model is loading - after opening the screen or choosing another hall - the **Loading the hall model…** indicator is shown over the model; it disappears when the scene is ready.

### Moving around the model

* **left mouse button + drag** — rotate the view,
* **right mouse button + drag** — pan the view,
* **mouse wheel** — zoom in and out,
* buttons on the left of the model — **Zoom in**, **Zoom out**, **Start view**, **Top view**.

The hall wall facing the camera is hidden automatically so that it does not block the view.

## “Live state” mode

The state of every machine is shown on the model in three ways:

* a **stack light** on the machine,
* a **floor outline** in the state colour,
* a **plate** with the station number, name and state — when the view is zoomed out, plates are shortened so that they do not cover the hall.

The colour matches the machine state defined in the [**Status configurator**](https://docs.omnimes.com/doc/status-configurator-4rNWOyTTbE) (e.g. green – running, amber – stop, red – failure). Running machines are animated (e.g. spindles, robot arms), and forklifts and AGVs drive along their routes.

  
**Indicators above the model:**

| Indicator | Meaning |
|-----------|---------|
| **Live**  | number of signals received from the floor and the time since the last one |
| **Running** | machines producing / all machines in the model |
| **Stops** | machines in a planned or unplanned stop |
| **Failures** | machines in failure |

  
**Station cards** list the machines in process order: station number, name, state and a selected measurement. Clicking a card or a machine on the model flies the view to the machine and opens the **details panel** with the device type, machine, line, time since the state changed, number of operators and all current measurements.

 ![](https://docs.omnimes.com/api/files.get?sig=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJrZXkiOiJ1cGxvYWRzLzRlMDdmZmNhLThmZjAtNDYxYy1iYjEyLTA2OTEyZGRiOGQzNi9lZDdkZTllNi1kYzc2LTRmNDAtYmY2Ny1iYzIxZDM2MWRjYzAvaG9sb2dyYW1fZW5faG9sb19zemN6ZWdvbHkucG5nIiwidHlwZSI6ImF0dGFjaG1lbnQiLCJpYXQiOjE3OTU0MTAwMDAsImV4cCI6MTc5NTQ5NjQwMH0.shEq0JNO7zoEUKfElOE6G9ZsW9v0i1ksRwEgmY2RUUM)

### View layers


:::tip
3D Hall → toolbar → Layers

:::

 ![](https://docs.omnimes.com/api/files.get?sig=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJrZXkiOiJ1cGxvYWRzLzRlMDdmZmNhLThmZjAtNDYxYy1iYjEyLTA2OTEyZGRiOGQzNi9mMjgxODIwZS1jYWY0LTQyZmUtYjYxMy02MmU0OTFjM2VlZmYvaG9sb193YXJzdHd5LnBuZyIsInR5cGUiOiJhdHRhY2htZW50IiwiaWF0IjoxNzk1NDEwMDAwLCJleHAiOjE3OTU0OTY0MDB9.F7iqRGiAZ-l95HMWNxOYJPCpVc5i2_LuLSZoVB_SRVM)

The **What to show on the model** window switches parts of the view on and off independently (from version 4.10.0):

| Layer | What it shows |
|-------|---------------|
| **Machine names** | plate with the station number and name |
| **Machine state** | state badge above the machine (close-up view) |
| **Parameters** | current measurements above the machines — a single line of values from afar, a name – value table close up |
| **Utility consumption** | markers of the largest utility consumers above the machines and the ranking bar above the model (from version 4.11.0, see *Top utility consumers*) |
| **Zones and lines** | outlines and names of line zones on the floor |
| **Material flow** | floor arrows and parts moving between stations |
| **Lighting** | ceiling luminaires and light pools on the floor (when the model contains lighting) |

With **Parameters** on, the **Which parameters** field selects the measurements to show, e.g. only power and temperature; an empty field means the first measurements of each machine. When a layer is off, the **Layers** button shows how many are on. The browser remembers the setting.

### Recommendations on the machine card

 ![](https://docs.omnimes.com/api/files.get?sig=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJrZXkiOiJ1cGxvYWRzLzRlMDdmZmNhLThmZjAtNDYxYy1iYjEyLTA2OTEyZGRiOGQzNi8wMGVjNGQ3OC00ZTcyLTQ0ZDAtYjc3Mi1mM2U5NTY5NTVkOTAvaG9sb19yZWtvbWVuZGFjamUucG5nIiwidHlwZSI6ImF0dGFjaG1lbnQiLCJpYXQiOjE3OTU0MTAwMDAsImV4cCI6MTc5NTQ5NjQwMH0.xMhVPyCu7bxIoLRAmrAvqPwoygCJxolReBLoYWPOtDU)

The machine details panel has a **Recommendations** section (from version 4.10.0) — a hint on why the machine has stopped and what to do. Above the list are indicators from the last 7 days: **Availability**, number of **Failures**, **MTBF** (mean operating time between failures) and **MTTR** (mean failure duration).

Recommendations are built from data collected in OmniMES — no predictive model:

* **machine state history from the last 7 days** — the same one Monitoring shows: how long the current state has lasted and how long it usually lasts, share of running, stops and failures, micro-stops (shorter than 5 min),
* **machine measurements** — the current value against the typical 7-day range, and power draw while stopped,
* **neighbouring stations in the 3D hall flow** — whether the previous station is feeding material and the next one is taking it.

| Situation | Example hint |
|-----------|--------------|
| failure   | how long it has lasted, how many failures there were in 7 days and their average duration; escalate when it lasts longer than 3/4 of earlier ones |
| unplanned stop | “the previous station has stopped too — start there” or “the next station is not taking parts”; when neighbouring stations are running — the cause is at this machine |
| running   | warning when the next station has stopped (risk of blocking) or the previous one is not feeding material |
| history   | micro-stops, availability below 75%, a failure more often than every 24 h of operation |
| measurements | a value outside its typical range (e.g. temperature) with a hint on what to check; power draw while stopped with an estimate in kWh |


:::info
Recommendations recognise running, stops and failures exactly like Monitoring, so their accuracy depends on the machine status configuration in the [**Status configurator**](https://docs.omnimes.com/doc/status-configurator-4rNWOyTTbE). The AI assistant gets the same data through MCP to answer “why has the machine stopped” in its own words.

:::

### Top utility consumers

 ![](https://docs.omnimes.com/api/files.get?sig=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJrZXkiOiJ1cGxvYWRzLzRlMDdmZmNhLThmZjAtNDYxYy1iYjEyLTA2OTEyZGRiOGQzNi84M2ZkOTJkYy02NmMwLTQzMjUtYjJjYi1mMDcxNzZlYTc4NTgvaG9sb19tZWRpYS5wbmciLCJ0eXBlIjoiYXR0YWNobWVudCIsImlhdCI6MTc5NTQxMDAwMCwiZXhwIjoxNzk1NDk2NDAwfQ.rXZfTp75t2pQZ60bZcW_v1_6vBtS4Bw3GkXjTSna4i8)

The **Top utility consumers** bar above the model shows which machines use the most electricity, water, gas, compressed air or heat (from version 4.11.0). These are recommendations for the whole hall — hints for a single machine are on its card.

* **24 h / 7 days / 30 days** — the period consumption is calculated for,
* for each selected parameter: the utility icon, total consumption in the period and the **three largest consumers** with their share of the total; clicking a consumer zooms to the machine on the model and opens its details panel,
* **Recommendations** — expands a list of hints above the model (the button shows their number, orange when there are warnings); clicking a hint zooms to the machine it concerns,
* **Utility parameters** — choosing measurements and assigning the utility (see below).

On the model, the same consumers have a **marker above the plate**: a dark badge with the utility icon and their rank, and close up also their share of the total. The bar and the markers are the **Utility consumption** layer — they work in *Live state* mode.

**Choosing parameters and assigning the utility**

 ![](https://docs.omnimes.com/api/files.get?sig=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJrZXkiOiJ1cGxvYWRzLzRlMDdmZmNhLThmZjAtNDYxYy1iYjEyLTA2OTEyZGRiOGQzNi85ZWMwMzg1ZC1lY2VlLTQ5NDYtYWExMC1jN2I0MzdkZTc3ZWMvaG9sb19tZWRpYV9wYXJhbWV0cnkucG5nIiwidHlwZSI6ImF0dGFjaG1lbnQiLCJpYXQiOjE3OTU0MTAwMDAsImV4cCI6MTc5NTQ5NjQwMH0.DUllV4pcACM1xBoeIkTUsIKMBJl_dwPglE4ca7FYrNw)

The **Utility parameters** window is available to users with permission to the **3D Hall settings** screen. It lists the measurements of the 3D hall machines (names as in the Status configurator). Tick the measurements that represent consumption and choose the utility: **Electricity**, **Water**, **Gas**, **Compressed air**, **Heat / steam** or **Other utility** — the utility determines the icon and the wording of the hints. Up to 6 parameters can be selected; the choice is saved in the 3D hall and applies to all its users. When opened for the first time, the window ticks measurements with a consumption unit and suggests the utility from the name and unit.

| Measurement | How consumption is calculated |
|-------------|-------------------------------|
| cumulative counter (e.g. kWh, m³) | the counter increase in the period; a counter reset is ignored |
| instantaneous value (e.g. W, kW, m³/h, l/min) | consumption over time — e.g. power in W and kW counted together as kWh, flow in m³/h as m³ |
| other measurement | average in the period — ranking without shares |

Recommendations are based on data collected in OmniMES — no predictive model:

| Situation | Example hint |
|-----------|--------------|
| consumption growth | hall consumption grew by at least 15% or a top machine's by at least 25% compared with the previous period of the same length — check whether production has grown |
| base load | the machine's consumption does not drop below half of its average during breaks — a hint depending on the utility: standby and switching off during stops, compressed-air leaks, water leaks, burner operation, valves and insulation |
| largest consumers | three consumers use most of the utility — the place to start saving |
| no data   | the measurement sent no values in the period or its values decrease, so they do not look like a counter — check the unit in the [**Status configurator**](https://docs.omnimes.com/doc/status-configurator-4rNWOyTTbE) |


:::info
Until parameters are selected, only users who can set them see the bar. When a counter started counting during the period (e.g. a new machine), the ranking covers data from that moment — the tooltip on the consumer shows “data since…”.

:::

### Hall lighting

The model can contain ceiling luminaires linked to lighting circuits monitored in OmniMES like machines (from version 4.10.0). The luminaires show the live state of the circuit:

* **circuit on** — the luminaires light up and light pools appear on the floor below,
* **economy mode** — the luminaires dim,
* **circuit off** — the luminaires switch off,
* **circuit failure** — the luminaires flicker.

Lighting circuits have station cards and a details panel like machines (e.g. state, power, illuminance, energy). The AI assistant adds luminaires to the model through MCP; the **Lighting** layer hides them, e.g. in the top view.

## “Simulation” mode

The simulation replays the flow of parts through the stations of the model, using the cycle times stored in the 3D hall. Parts move across the model between stations, and the outline of each station shows its state. The simulation does not affect production or any data in the system.

 ![](https://docs.omnimes.com/api/files.get?sig=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJrZXkiOiJ1cGxvYWRzLzRlMDdmZmNhLThmZjAtNDYxYy1iYjEyLTA2OTEyZGRiOGQzNi83ZDM0MzIxZi01ZGQ5LTRlMmUtYWNmYy1iYmQ5NzFkN2E5MmUvaG9sb2dyYW1fZW5faG9sb19zeW11bGFjamEucG5nIiwidHlwZSI6ImF0dGFjaG1lbnQiLCJpYXQiOjE3OTU0MTAwMDAsImV4cCI6MTc5NTQ5NjQwMH0.MI1Dn6MZFrBHgXCoHG_-gHM4rNkj3eqS2L5OOrA1Gu0)

  
The simulation bar (at the bottom of the model):

* **Run simulation / Pause**,
* **speed** — ×1, ×10, ×60, ×300,
* **Restart** (icon) — starts the simulation again,
* **Calculate a shift (8 h)** — calculates a whole shift instantly,
* **Simulation parameters** — a window with the station parameters,
* station state legend: **working**, **blocked**, **waiting for parts**, **stopped**.

The indicators above the model show **Throughput** (pcs/h and simulated time), **Finished** (finished parts and work in progress – WIP) and the **Bottleneck**, i.e. the station limiting the output. Station cards show the cycle, utilization and queue of each station.

### Simulation parameters

 ![](https://docs.omnimes.com/api/files.get?sig=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJrZXkiOiJ1cGxvYWRzLzRlMDdmZmNhLThmZjAtNDYxYy1iYjEyLTA2OTEyZGRiOGQzNi9lYjhlMThhYy04OTlkLTRkYmYtYjk4Ny02MWJmNzVkYjgzZmEvaG9sb2dyYW1fZW5faG9sb19wYXJhbWV0cnkucG5nIiwidHlwZSI6ImF0dGFjaG1lbnQiLCJpYXQiOjE3OTU0MTAwMDAsImV4cCI6MTc5NTQ5NjQwMH0.8mY-MpuJ-Pztpi3X24_Ur71frTc6bC4ls25U2pUVFmw)

* for each station: **Cycle [s]**, **Slots**, **Run time between stops [s]**, **Stop [s]**,
* for the whole model: **Material arrives every [s]** — leave it empty when material is always available,
* **Buffers between stations** — buffer capacity **[pcs]**,
* **Values from the 3D hall** — restores the values stored in the model.

The cycle and slots of a selected station can also be changed in the details panel after clicking the station on the model or its card.


:::info
Parameter changes apply only to the current simulation and are not saved to the 3D hall. Permanent cycle times are changed by the AI assistant over MCP.

:::

  
**Example — finding the bottleneck:**


1. Click **Calculate a shift (8 h)** and read the station in the **Bottleneck** indicator.
2. Click the card of that station and change its **Cycle** or the number of **Slots**.
3. Click **Calculate a shift (8 h)** again and compare the **Throughput** — check whether it went up or the bottleneck moved to another station.

## 3D hall settings (window)


:::tip
3D Hall → toolbar → Settings

:::

 ![](https://docs.omnimes.com/api/files.get?sig=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJrZXkiOiJ1cGxvYWRzLzRlMDdmZmNhLThmZjAtNDYxYy1iYjEyLTA2OTEyZGRiOGQzNi84ODcyYWIxYi0xNDQ5LTQ0ODAtODRmMS05ZjhmNmUwZDBkMDgvaG9sb2dyYW1fZW5faG9sb19rb25maWd1cmFjamEucG5nIiwidHlwZSI6ImF0dGFjaG1lbnQiLCJpYXQiOjE3OTU0MTAwMDAsImV4cCI6MTc5NTQ5NjQwMH0.u0Tgn1od4eQOJ-yhioUIxNB18w7Gu-ZAxVmKo0rQ24Y)

* the 3D hall **Name** and **Description**,
* **Show labels when opened** — the default state of the **Machine names** layer, until the user changes the layers in their browser,
* **Start view** — **Save current view** (the current camera position becomes the start view) or **Fit the whole hall**,
* **Elements** — the list of model elements; for each one you can choose the **OmniMES machine** it is linked to, or **remove** it. In a hall from a .glb file, model parts connected to machines have the type **Part of the .glb model** — removing such an element disconnects the machine from the part, and the part itself stays in the model.

Changing a link or removing an element creates a new 3D hall version. Shapes and the hall layout are changed by the AI assistant over MCP or by a new .glb file (see *Hall from a .glb file*).

## Connecting machines to model parts


:::tip
3D Hall → toolbar → Connect machines

:::

 ![](https://docs.omnimes.com/api/files.get?sig=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJrZXkiOiJ1cGxvYWRzLzRlMDdmZmNhLThmZjAtNDYxYy1iYjEyLTA2OTEyZGRiOGQzNi9iYzYyOTQxZC05NTFlLTRlNDctYWU3ZC00MTI3YzZmZGY5MWMvaG9sb19wb2RwaW5hbmllLnBuZyIsInR5cGUiOiJhdHRhY2htZW50IiwiaWF0IjoxNzk1NDEwMDAwLCJleHAiOjE3OTU0OTY0MDB9.lX83ItIzD9djGBmALddctozYOZKvOt9An3h9lARGPb4)

In a hall from a .glb file, OmniMES machines are connected to **parts of the model** — e.g. to the press body from a CAD drawing. A connected part gets the same as a machine in a model built by the AI assistant: a signal tower, a state outline on the floor, a label, a station card and the details panel with live measurements. There are three ways to connect machines:

* **automatically on import** — when a part has the name of a machine (letter case, Polish characters, spaces and punctuation do not matter) or when the file comes from an OmniMES export,
* **manually** — with the **Connect machines** button described below,
* **by the AI assistant** — many machines at once; the prompt is prepared by the wizard in **3D Hall settings** (the **Connect signals** action).

**Connecting a machine manually — step by step:**


1. Click **Connect machines** on the toolbar. A panel opens to the right of the model with the number of **Connected machines** and the list of **Machines without a part**.
2. Click the part of the model you want to connect. The selected part is highlighted in orange, and the panel shows its name from the file and its size.
3. Check the part level. A CAD file usually has several levels (hall, line, machine, assembly, detail), and a click usually hits a detail, so the application suggests the whole machine: a part that is already connected, a part with the name of a machine, or the largest part that is not a whole line or hall. **Larger part** and **Smaller part** change the level, and **Place in the model** shows the whole path of the part — every level can be clicked. **Show** zooms the view to the selected part.
4. Choose the **Machine**. The list has two groups: **Without a model part** and **Connected elsewhere – will be moved here**. When the part name matches a machine, the application selects it and shows a hint. You can also click a machine in the **Machines without a part** list first, and then its part in the model.
5. Click **Connect**. The state outline, the label and the station card appear at once, and the camera does not move, so you can go on to the next machine.
6. Finish with **Done** (or the Esc key).

| Situation | What happens |
|-----------|--------------|
| the machine is connected to another part | saving moves it to the selected part — one machine has one model part |
| the selected part is already connected | the panel shows **Connected to machine**; choose another machine or click **Disconnect** |
| the part lies inside a part of another machine or contains it | the panel warns and does not allow saving — choose a larger or smaller part, or disconnect the other one first |

In the connecting mode a click on a station card selects the part of that machine. The machine list covers the machines in the hall scope (plant, lines or selected machines).


:::info
Every connection and disconnection saves a new 3D hall version (source: application) — you can bring earlier connections back in **Version history**. OmniMES computes the position and size of the part for the state outline from the file, so the outline always fits the solid.

:::

## Version history


:::tip
3D Hall → toolbar → Version history

:::

 ![](https://docs.omnimes.com/api/files.get?sig=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJrZXkiOiJ1cGxvYWRzLzRlMDdmZmNhLThmZjAtNDYxYy1iYjEyLTA2OTEyZGRiOGQzNi80ODg4YmM3OC1mNjc0LTRhYjgtOWU0NS1jOTEzNDhiMWQ2YjkvaG9sb2dyYW1fZW5faG9sb193ZXJzamUucG5nIiwidHlwZSI6ImF0dGFjaG1lbnQiLCJpYXQiOjE3OTU0MTAwMDAsImV4cCI6MTc5NTQ5NjQwMH0.YDadJRxuqXE264US4euaadsg-4SXNiKqEBerh8Wqg9s)

  
Every save of the model creates a new version. The table shows the **Version**, **Date**, **Source** of the change (MCP, app, restore), **AI model**, **User**, number of **Elements** and the **Note** describing the change. **Restore** saves the selected earlier version as the new current one — the whole history stays intact.

## Building and extending the model (3D Hall settings page)


:::tip
Menu → System settings → 3D Hall settings

:::

  
The hall model is built by an **AI assistant connected to OmniMES over MCP** — or comes from a ready 3D file (see *Hall from a .glb file*). The assistant reads the plant structure (lines, machines and signals) and builds a 1:1 model: machines at real-world sizes and in process order, transport aisles, line zones, racks, buffers, forklifts and the part flow with cycle times. The best results come from the **recommended model in General configuration → AI** - the **Advanced** tier model (**Claude Opus 5.5** by default) - and newer models. The screen shows the name of the recommended model, but you choose it yourself in your AI app; OmniMES cannot enforce it.

The scene is saved by an assistant connected with the **personal connection** of a user who may edit the 3D Hall (the **3D Hall settings** screen in the permissions), or with the assistant service account. Each scene version records the user who connected the assistant (the **User** column in the version history).

 ![](https://docs.omnimes.com/api/files.get?sig=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJrZXkiOiJ1cGxvYWRzLzRlMDdmZmNhLThmZjAtNDYxYy1iYjEyLTA2OTEyZGRiOGQzNi8yNmZjYzliNi05N2E3LTQwY2ItYmQ2MC1lM2MyYTJjNWQ0MDQvaG9sb191c3Rhd2llbmlhLnBuZyIsInR5cGUiOiJhdHRhY2htZW50IiwiaWF0IjoxNzk1NDEwMDAwLCJleHAiOjE3OTU0OTY0MDB9.dDkWnuLryGvwkuDl-tr9VDH23rI6C0tFPUMTjJORvjo)

### List of 3D halls

The table shows the 3D hall name and description, plant, scope, version, AI model, number of elements and linked machines, and the date of the last change. A hall from an imported model has the **from .glb file** tag next to its name. The list can be narrowed down to one plant and refreshed, and the **Import .glb** button above the list creates a new hall from a file (see *Hall from a .glb file*). Available actions:

* **Open** — opens the model in the 3D Hall module,
* **Extend over MCP** — prepares a prompt to extend this 3D hall (see below),
* **Export .glb** — saves the hall model to a .glb file,
* **Import .glb** — a new .glb file in this hall (a new version),
* **Settings** and **Version history** — the same windows as in the 3D Hall module (the settings window is titled **3D hall settings**),
* **Delete 3D hall** — the 3D hall disappears from the list; the scene and version history stay in the database.

### Prompt for the AI assistant — step by step


1. Connect the AI assistant to the OmniMES MCP server — user menu → [**AI assistant connection**](https://docs.omnimes.com/doc/ai-assistant-connection-Xbr2840qoC). In your AI app choose the recommended model (the **Advanced** tier, Claude Opus 5.5 by default) or newer.
2. In the **3D hall over MCP – new or extended** section, choose **what to prepare**: **New 3D hall**, **Extend a 3D hall** or — when the system has a hall from a .glb file — **Connect signals** (the assistant connects machines to model parts; choose the hall from the file).
3. For a new 3D hall choose the **Plant** and the **Model scope**:
   * **Whole plant** — all lines and machines of the plant,
   * **Lines** — selected production lines,
   * **Selected machines** — one machine or several, e.g. a section of a line.

   Change the **3D hall name** if needed.
4. To extend, choose the **3D hall to extend** and, optionally, **Machines to add** (plant machines that are not in the model yet). Describe other changes in the prompt.
5. Click **Copy prompt** and paste it to the AI assistant.
6. The assistant saves the model. After every save OmniMES checks the model and reports back to the assistant: missing machines from the scope, machines outside the scope, duplicated machines, overlapping elements or elements outside the hall, and machines outside the flow. The assistant fixes the model until the check reports nothing.
7. Open the finished model in **Preview → 3D Hall**.


:::info
The prompt contains the exact identifiers of the plant, lines and machines, so the assistant builds the model from the selected machines only. OmniMES rejects a model that contains machines or lines from outside the plant.

:::

## Hall from a .glb file


:::tip
Menu → System settings → 3D Hall settings → Import .glb

:::

Instead of a model built by the AI assistant, a hall can be loaded from a **3D file** — e.g. from a plant drawing in a CAD program, from Blender or from a machine model supplied by its maker. The application then draws the hall from the file, and OmniMES machines are connected to its parts (see *Connecting machines to model parts*).

**Accepted files:**

* the **binary glTF 2.0 (.glb)** format — a single file with embedded geometry and textures, up to **48 MB**,
* also files from outside OmniMES, with **Draco** or **meshopt** geometry compression and **KTX2** (Basis Universal) textures — the decoders are part of the application and work without internet access,
* save a model in another format (e.g. STEP, FBX, OBJ) or a **.gltf** with separate files as .glb, e.g. in Blender: **File › Export › glTF 2.0**, format **glTF Binary**.

Only damaged files, files that are too large or files that refer to external files are rejected — with a message on what to fix.

### Importing a model from a .glb file

 ![](https://docs.omnimes.com/api/files.get?sig=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJrZXkiOiJ1cGxvYWRzLzRlMDdmZmNhLThmZjAtNDYxYy1iYjEyLTA2OTEyZGRiOGQzNi84ZGJjYzMzNS03ZDRhLTQ5YzMtOWNmMi0zYzNlMDQwZjU0MDIvaG9sb19nbGJfaW1wb3J0LnBuZyIsInR5cGUiOiJhdHRhY2htZW50IiwiaWF0IjoxNzk1NDEwMDAwLCJleHAiOjE3OTU0OTY0MDB9.cocTx7uN8CIVkVXF3zVgdKdwJSMtyzm2j__0rBYmtUw)


1. In **3D Hall settings** click **Import .glb**.
2. Choose the **.glb file**. The hall name is suggested from the file name — change the **3D hall name** if needed.
3. Choose the **Plant** and, in **Assign to**, the hall scope: **Whole plant**, **Lines** or **Selected machines**. The scope decides which machines can be connected to model parts.
4. Set the **Model units**: **Automatic** (a model larger than 1.5 km is treated as saved in millimetres), **Metres**, **Centimetres**, **Millimetres (typical for CAD)** or **Inches**.
5. Tick **Draw the hall walls and columns around the model** when the file contains machines only, without the building.
6. Click **Import**.

 ![](https://docs.omnimes.com/api/files.get?sig=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJrZXkiOiJ1cGxvYWRzLzRlMDdmZmNhLThmZjAtNDYxYy1iYjEyLTA2OTEyZGRiOGQzNi8wNGRkMjUwZi1kZmFkLTRlZWEtOGM2ZS1iZTFkMTUzNzg3ZDUvaG9sb19nbGJfd3luaWsucG5nIiwidHlwZSI6ImF0dGFjaG1lbnQiLCJpYXQiOjE3OTU0MTAwMDAsImV4cCI6MTc5NTQ5NjQwMH0.uJ1BZEj6gxX4CKvXSxtmI9f72ToMBMaGsgy4yGyigNA)

The **Model imported** window sums up the import: the file and its size, the number of model parts and triangles, the scale (when the file units were converted to metres) and **Connected machines: X of Y**. Machines connected automatically show their live state at once. Connect the others with:

* **Open** — goes to the hall, where the **Connect machines** button is,
* **Connect signals with Claude** — the wizard prepares a prompt for the AI assistant, which connects many machines at once.

The model is centred in the hall and stands on the floor. The AI assistant can correct the position, rotation and scale of the model over MCP.

### A new file in an existing hall

The **Import .glb** button in a hall row loads a new file into this hall, e.g. after changes in CAD. A new version is created — the previous one stays in **Version history** and you can go back to it. The hall scope does not change, and machines connected to parts with the same names stay connected.

### Exporting a hall to a .glb file

The **Export .glb** button in a hall row saves its model to a .glb file — for every hall, including one built by the AI assistant. You can open the file e.g. in Blender or in Windows 3D Viewer and import it back after your changes.

* The file contains the building and the hall equipment: machines, racks, conveyors and forklifts. It has no live data and no animations.
* Labels, state outlines on the floor and the ground around the hall are left out.
* Every machine is a separate part in the file, named after the machine, with the OmniMES machine identifier in the part data. That is why machines connect by themselves after the file is imported again.
* KTX2 textures of an imported model are saved to the file as PNG, so programs without KTX2 support open it too.

3D Hall brings the hall layout, the current machine states and a way to test flow changes before they reach production together in one view.

---

**Documents**

- [OmniPlatform](https://docs.omnimes.com/s/cb8b19e0-ec6d-4e1a-8690-b0ddd67ad1cd/doc/omniplatform-7z9SIECi68)
- [Omnienergy](https://docs.omnimes.com/s/cb8b19e0-ec6d-4e1a-8690-b0ddd67ad1cd/doc/omnienergy-56aRDgnYFZ)
- [Omnimes](https://docs.omnimes.com/s/cb8b19e0-ec6d-4e1a-8690-b0ddd67ad1cd/doc/omnimes-eGDa0U5cyr)